Pupil Labs Neon

Integration guide for using the Pupil Labs Neon eye tracker with HyperStudy experiments through the HyperStudy Bridge.

Overview

The Pupil Labs Neon is a lightweight, mobile eye tracker that provides real-time gaze data. It connects to HyperStudy via the Bridge application, which communicates with the device through its REST API and Lab Streaming Layer (LSL) for gaze data streaming.

Signal Flow

HyperStudy Web App → HyperStudy Bridge → Pupil Labs Neon (REST API + LSL)

Features

  • Real-Time Gaze Streaming: Live gaze position and pupil diameter at up to 200 Hz via LSL
  • Event Annotations: Timestamped event markers synchronized with the Neon's recording timeline
  • Automatic Discovery: Find Neon devices on the network via LSL without manual IP entry
  • 9-Point Calibration: Screen-space calibration for accurate gaze mapping
  • Recording Control: Start/stop recordings on the Neon from within HyperStudy
  • Battery Monitoring: Real-time battery level displayed during setup
  • Gaze Overlay: Live gaze visualization during experiments via the Gaze Overlay component

Prerequisites

Hardware

  • Pupil Labs Neon eye tracker
  • The Neon and the Bridge machine must be on the same network (WiFi or Ethernet)

Software

  • HyperStudy Bridge v0.8.22 or later
  • Pupil Labs Neon Companion app (running on the Neon's companion device)

Connection Methods

The Bridge uses Lab Streaming Layer (LSL) to discover Neon devices on the network automatically:

  1. Launch the Bridge and ensure the Pupil module is active
  2. In the HyperStudy experiment setup, click Discover Devices
  3. Available Neon devices appear in the list
  4. Select your device and click Connect

Manual IP Connection

If automatic discovery doesn't find your device:

  1. Find the Neon's IP address in the Companion app settings
  2. Enter the IP address in the setup dialog
  3. Click Connect

The last connected IP is remembered for future sessions.

Configuration

Experiment Designer Settings

In the Experiment Designer, navigate to Device IntegrationPupil Labs Neon:

SettingDefaultDescription
EnabledfalseEnable Pupil Labs Neon integration
Gaze StreamingfalseStream real-time gaze data to HyperStudy
Require CalibrationfalseRequire gaze calibration before experiment starts

Gaze Data

When gaze streaming is enabled, the following data is available in real-time:

FieldDescription
gazeX, gazeYNormalized gaze position (0-1)
pupilDiameterPupil diameter in millimeters
confidenceGaze confidence metric
timestampUnix timestamp
sampleCountTotal samples received

The system auto-detects whether the device reports pixel coordinates or normalized values and handles the conversion.

Calibration

When calibration is enabled, participants complete a 9-point calibration during experiment setup.

How It Works

  1. A calibration target appears at 9 screen positions (10%, 50%, 90% on each axis)
  2. The participant fixates on each target
  3. The system collects gaze samples for 1.5 seconds per point (after 500ms settling time)
  4. A 6-parameter affine transform is computed to map gaze coordinates to screen positions
  5. A quality score (RMS error) is reported

Calibration Quality

RMS ErrorQuality
< 4%Excellent
4-8%Good
> 8%Warning — consider recalibrating

A minimum of 30 samples per point is required. If insufficient samples are collected at a point, the system prompts for recalibration.

Event Annotations

HyperStudy automatically sends timestamped event markers to the Neon's recording for synchronization. These annotations appear in the Neon's recording timeline.

Annotated Events

EventAnnotation Format
Experiment startexperiment_start:<name>
Experiment endexperiment_end
State transitionstate_transition:<index>:<name>
Component startcomponent_start:<type>
Component endcomponent_end:<type>
Component responsecomponent_response:<type>
Triggertrigger:<code>
Custom markermarker:<label>

These markers enable precise alignment of experiment events with the eye tracking data during analysis.

Usage

Basic Workflow

  1. Power on the Neon and ensure the Companion app is running
  2. Verify network — the Neon and Bridge machine must be on the same network
  3. Launch HyperStudy Bridge on the experiment machine
  4. Connect to the Neon (automatic discovery or manual IP)
  5. Start recording on the Neon (optional — can be automatic)
  6. Run your experiment — event annotations are sent automatically
  7. Stop recording and disconnect when finished
  8. Export data from the Neon Companion app for analysis

With Gaze Overlay

To show live gaze visualization during experiments:

  1. Enable Pupil Labs Neon in Device Integration settings
  2. Enable Gaze Streaming
  3. Enable the Gaze Overlay global component
  4. Optionally enable Require Calibration for screen-mapped gaze
  5. Configure the Gaze Overlay appearance (dot size, color, trail, etc.)

Setup Flow for Participants

During experiment setup, participants see:

  1. Bridge connection check — verifies the Bridge is running
  2. Device discovery — finds Neon devices on the network
  3. Connection — connects to the selected device
  4. Gaze stream test — verifies gaze data is flowing
  5. Calibration (if required) — 9-point calibration with live preview
  6. Live gaze preview — confirms everything is working

Participants can skip setup if allowed by the experimenter's configuration.

Troubleshooting

Device Not Discovered

  • Verify the Neon and Bridge machine are on the same network
  • Check that the Companion app is running and connected
  • Try manual IP connection as a fallback
  • Restart the Bridge's LSL discovery

No Gaze Data

  • Ensure gaze streaming is enabled in the experiment's Device Integration settings
  • Verify the Neon is properly positioned on the participant
  • Check that the Bridge shows an active gaze stream
  • Restart the gaze stream from the setup interface

Poor Calibration Quality

  • Ensure the participant keeps their head still during calibration
  • Verify the Neon is properly seated and not shifting
  • Check that the room lighting allows good pupil detection
  • Try recalibrating — sometimes a second attempt improves results

Connection Lost During Experiment

  • The system will attempt to reconnect automatically
  • If the Neon's battery dies, gaze data will stop but the experiment continues
  • Check the Bridge status window for connection diagnostics